BoxMate
SKU: AL-BM-LV02V
- Robust & Portable: Economical suitcase-style controllers housed in durable polymer casing with internal galvanised steel reinforcement.
- Voltage & Channel Options: Available in Direct Voltage or Low Voltage versions, with 2 to 8 channel configurations.
- Power & Safety: 400–415V / 3-phase / 50–60Hz power supply, CEE 32A 5-pole socket, automatic phase correction on LV, manual on DV, and 1 circuit breaker per group of 2 hoists.
- Flexible Control: Supports local or optional remote ordering; hoist connections via CEE, CEE + Harting, or CEE + Socapex depending on model.
- High Capacity: Maximum power per channel up to 20 kW cumulative across all channels based on 32 A.
- Optional Upgrades: SOCAPEX or Harting connectors, LINK interface card for daisy-linking with other controllers or wired remotes, optional remote control with Up/Down + E-Stop, and variable cable lengths.
- Channel Configurations:
- BoxMate 2 Channel – LV, phase reversal switch, 2 × 6-pin Harting connectors, non-linkable
-
BoxMate 4 Channel – LV, phase reversal switch, 4 × 6-pin Harting connectors, non-linkable
-
BoxMate 4 Channel – LV, phase reversal switch, 4 × 6-pin Harting connectors, linkable
-
BoxMate 6 Channel – LV, phase reversal switch, 6 × 6-pin Harting connectors, non-linkable
-
BoxMate 8 Channel – LV, phase reversal switch, 8 × 6-pin Harting connectors, non-linkable
Description
Available in: Box Mate 2 Channel – LV, phase reversal switch, 2 x 6 pin Harting Connectors, non-linkable. Box Mate 4 Channel – LV, phase reversal switch, 4 x 6 pin Harting Connectors, non-linkable Box Mate 4 Channel – LV, phase reversal switch, 4 x 6 pin Harting Connectors, linkable Box Mate 6 Channel – LV, phase reversal switch, 6 x 6 pin Harting Connectors, non-linkable Box Mate 8 Channel – LV, phase reversal switch, 8 x 6 pin Harting Connectors, non-linkable
Technical specifications
- Available in Direct Voltage or Low Voltage versions
- Available in 2 to 8 channel versions
- Power supply 400-415V / 3 phases / 50-60 Hz
- CEE 32 Amp 5-pole power socket
- Automatic phase correction on low voltage and manual correction via power connector on direct voltage.
- Local ordering or remote ordering (optional)
- Hoist connections via CEE or CEE + Harting or CEE + Socapex sockets (depending on the model)
- Suitcase Controller
- 1 circuit breaker per group of 2 hoists
- Maximum power per channel (kW): 20 kW maximum cumulative across all channels based on 32 A
Options:
- SOCAPEX or HARTING
- LINK interface card for Daisylink-type connection with a controller and/or a wired remote
- Remote control for controller with Up/Down + emergency stop
- Different cable lengths for the connection between the remote control and the controller